Free for restaurants across FloridaHow it works
Florida Commercial Kitchen Connect Get quotes

Commercial kitchen hoods and exhaust in Florida

Facts checked 2026-11-15.

A new stainless kitchen hood with baffle filters over a cooking line
A new hood over a cooking line.

A kitchen hood is one part of a system that also includes the grease duct, the roof fan and the makeup air. Florida's building code treats them together, and the whole system is tested before final approval. Send a request and an HVAC or mechanical contractor that serves your ZIP code gets it.

What the work covers

Requests in this category include a new hood, a new exhaust fan, filter exchange, grease containment, repairs, and air balance to close out a permit. Pick the one that fits on the form, since each goes to a company that does that kind of job.

Type I or Type II

The code sorts hoods into two types. A Type I hood goes over fryers, griddles, charbroilers and ranges that give off grease or smoke. A Type II hood goes over dishwashers and other equipment that gives off only heat or moisture.

A few appliances are excepted, such as electric units that pass the UL 710B low-grease test. Your building department decides whether yours counts.

Get prices for this job. Send one request and pick how many local companies quote it.

Get quotes

Airflow and the duct

How much air the hood must move depends on the cooking. The code sets a rate per foot of hood, higher for heavy cooking and for hoods in the middle of a room. A wall canopy over heavy cooking calls for 400 cubic feet per minute per foot, for example.

The duct that carries grease-laden air to the roof gets strict treatment. It needs thick steel, liquid-tight welded seams, cleanouts at set spacing and clearance from anything that can burn. Where it passes through walls or floors, it runs inside a fire-rated enclosure.

Makeup air and air balance

Air pulled out must be replaced. The code asks that makeup air roughly match exhaust, and that it start when the fan does. Plans include an outdoor air balance schedule, and the installer should hand you a copy.

Signs a hood system needs attention

Look for grease dripping from the hood or the roof fan base, smoke that lingers instead of rising, a kitchen that feels starved for air, or doors that pull hard when the fan runs. A missing or blocked access panel also needs a fix.

Adding or moving equipment

A new fryer or a shifted cooking line often changes what the hood and the suppression system must handle. Before you buy, ask a licensed company whether the current setup covers the change, and ask your building department whether it needs a permit.

Who may do the work

Florida licenses mechanical and sheet metal contractors, and the permit office decides which license it accepts for a hood and duct job. The fire suppression part takes a separate State Fire Marshal license. Look up any contractor on the DBPR license search.

Questions

Does every restaurant kitchen need a Type I hood?

A Type I hood is required over cooking that produces grease or smoke. Equipment that makes only heat or moisture can sit under a Type II hood.

Who tests a new restaurant hood before opening?

The Florida Mechanical Code calls for a performance test before final approval. It checks exhaust and makeup airflow and smoke capture, so ask your building department who it accepts to run it.

Where can I check a hood contractor's license in Florida?

Use the DBPR license search on myfloridalicense.com. Fire suppression companies are licensed separately through the State Fire Marshal.

Sources

  1. Florida Building Code, Mechanical 2023, chapter 5 (UpCodes copy)
  2. Florida Building Code, Building, chapter 9 (UpCodes copy)
  3. Florida Statutes 489.105, contractor definitions
  4. DBPR license search

Tell us what your kitchen needs. One short form reaches the local companies you choose.

Get quotes